Noise dose and TWA calculator

Noise dose is the share of a day's allowed noise a worker has taken: 100% is the limit. Enter each sound level and the time spent at it to get the dose and the 8-hour time-weighted average (TWA) under OSHA's rules (85 dBA action level, 90 dBA permissible limit) and the NIOSH recommended limit (85 dBA), with which limits are reached and how much loud time to cut.

Dose, %equals100 × (C₁ ÷ T₁ + C₂ ÷ T₂ + … + Cₙ ÷ Tₙ)

TOSHA, hoursequals8 divided by 2(L − 90) ÷ 5

TWAOSHAequals16.61 × log10(D ÷ 100) + 90

TNIOSH, hoursequals8 divided by 2(L − 85) ÷ 3

TWANIOSHequals10 × log10(D ÷ 100) + 85

C is the time at a level, T the time allowed at that level and L the A-weighted level in dBA. OSHA: 29 CFR 1910.95, Appendix A. NIOSH: Criteria for a Recommended Standard: Occupational Noise Exposure (1998), sections 1.1.1 and 1.1.3, which give T in minutes as 480 ÷ 2(L − 85) ÷ 3. Levels under 80 dBA add nothing, and under 90 dBA nothing to the OSHA PEL dose.
Noise levels over the shift

A-weighted, slow response. One row per level, with the time at it. Include the quiet parts of the shift too.

The Noise Reduction Rating on the package. Leave blank to skip.

Pre-filled with the worked example (illustrative). Levels from a sound level meter or the readings of a dosimeter. The result is an estimate, not a measurement.

OSHA 8-hour TWA

92.2 dBA

Dose 134.9%, all levels from 80 dBA, over 8 h.

OSHA action level

Reached

85 dBA TWA or a 50% dose. Levels from 80 dBA count; 5 dB exchange rate.

134.9% dose, TWA 92.2 dBA

A hearing conservation program is required: monitoring, audiometric testing, hearing protectors, training and records, 1910.95(c) to (o).

Time to cut: 2 h at 95 dBA and 2 h 7 min at 92 dBA moved to work below 80 dBA, to bring the dose down to 50%, and a little more to get under it.

OSHA permissible exposure limit

Over

90 dBA TWA or a 100% dose. Levels from 90 dBA count; 5 dB exchange rate.

116.0% dose, TWA 91.1 dBA

Over the permissible exposure limit: feasible engineering or administrative controls are required, and hearing protectors if the controls do not bring it within the limit, 1910.95(b)(1).

Time to cut: 38 min at 95 dBA moved to work below 90 dBA, to bring the dose down to 100%.

NIOSH recommended limit

Over

85 dBA TWA or a 100% dose. Levels from 80 dBA count; 3 dB exchange rate.

554.0% dose, TWA 92.4 dBA

At or over the NIOSH recommended limit: NIOSH recommends a hearing loss prevention program and controls to bring it below 85 dBA.

Time to cut: 2 h at 95 dBA and 3 h 12 min at 92 dBA moved to work below 80 dBA, to bring the dose down to 100%, and a little more to get under it.

Email me my results

Optional. Get these inputs and results in your inbox, with a link back to this calculator.

We may follow up about LeanSuite. See our Privacy Notice.

The working, step by step

For each level: the time allowed there (T, hours), then the time spent (C) divided by it. Dose = 100 × the sum of C ÷ T. Rows under the threshold add nothing.

OSHA, levels from 80 dBA (action level)

T = 8 ÷ 2^((L − 90) ÷ 5)

OSHA, levels from 80 dBA (action level): level, time, allowed time and fraction of the dose
L, dBAC, hT, hC ÷ T
924.006.060.660
882.0010.560.189
952.004.000.500

Dose = 100 × (0.660 + 0.189 + 0.500) = 134.9%
TWA = 16.61 × log10(134.9 ÷ 100) + 90 = 92.2 dBA

OSHA, levels from 90 dBA (PEL)

T = 8 ÷ 2^((L − 90) ÷ 5)

OSHA, levels from 90 dBA (PEL): level, time, allowed time and fraction of the dose
L, dBAC, hT, hC ÷ T
924.006.060.660
882.0010.56not counted
952.004.000.500

Dose = 100 × (0.660 + 0.500) = 116.0%
TWA = 16.61 × log10(116.0 ÷ 100) + 90 = 91.1 dBA

NIOSH, levels from 80 dBA (REL)

T = 8 ÷ 2^((L − 85) ÷ 3)

NIOSH, levels from 80 dBA (REL): level, time, allowed time and fraction of the dose
L, dBAC, hT, hC ÷ T
924.001.592.520
882.004.000.500
952.000.792.520

Dose = 100 × (2.520 + 0.500 + 2.520) = 554.0%
TWA = 10 × log10(554.0 ÷ 100) + 85 = 92.4 dBA

Next step

Want to track this every week?

Bring this result to a 45-minute demo and we will show where it fits in LeanSuite's Continuous Improvement for Safety.

Before you enter numbers

Getting levels and times you can trust

Use A-weighting and slow response. OSHA's limits are written for the A scale of a standard sound level meter at slow response (1910.95(a)), and NIOSH asks for the same. Measure in the worker's hearing zone, which OSHA's Technical Manual describes as a sphere about 2 feet across around the head.

A dosimeter beats a walk with a meter. The Technical Manual calls the noise dosimeter the primary instrument for compliance measurements. Worn for the whole shift, it records what the worker actually hears as they move. A meter reading per task works when each task is steady and you time each one honestly; NIOSH suggests a task-based approach for people who move between tasks.

Enter the whole shift. Include breaks and quiet work as rows below 80 dBA. They add no dose, but they show the full shift length. On shifts over 8 hours OSHA lowers only the action level and judges the PEL on the worst 8 hours (OSHA memorandum of 10 November 1999).

Use calibrated Type 2 or Type 1 instruments. The Technical Manual says other meters and phone apps can find noisy spots but cannot document compliance, and that instruments need a calibration check before and after each use.

This calculator does the arithmetic of Appendix A. It is not a substitute for a noise survey by a qualified person, it does not assess impact noise (the 140 dB peak limit), and it does not set up a hearing conservation program for you.

Worked example

Illustrative numbers, not a benchmark

An operator on an 8-hour shift: 4 hours at a press line measured at 92 dBA, 2 hours in the packing area at 88 dBA, and 2 hours at a grinding station at 95 dBA.

  1. 1OSHA time allowed: 92 dBA: 8 ÷ 2^0.4 = 6.06 h. 88 dBA: 8 ÷ 2^(−0.4) = 10.56 h. 95 dBA: 8 ÷ 2^1 = 4 h.
  2. 2OSHA dose, levels from 80 dBA: 100 × (4 ÷ 6.06 + 2 ÷ 10.56 + 2 ÷ 4) = 100 × (0.660 + 0.189 + 0.500) = 134.9%. TWA = 16.61 × log10(1.349) + 90 = 92.2 dBA. Over the 85 dBA action level.
  3. 3OSHA PEL dose, levels from 90 dBA: the 88 dBA time drops out. 100 × (0.660 + 0.500) = 116.0%, TWA 91.1 dBA. Over the PEL. To bring it to 100%: (116.0 − 100) ÷ 100 × 4 h = 0.64 h, about 38 minutes less at 95 dBA.
  4. 4NIOSH time allowed: 92 dBA: 8 ÷ 2^(7 ÷ 3) = 1.59 h. 88 dBA: 4 h. 95 dBA: 8 ÷ 2^(10 ÷ 3) = 0.79 h.
  5. 5NIOSH dose: 100 × (4 ÷ 1.59 + 2 ÷ 4 + 2 ÷ 0.79) = 100 × (2.520 + 0.500 + 2.520) = 554.0%. TWA = 10 × log10(5.540) + 85 = 92.4 dBA.
  6. 6Under the OSHA action level only by moving all 2 hours at 95 dBA and another 2 h 7 min of the 92 dBA work to quiet work. Not realistic, so the answer is quieter machines and a hearing conservation program.
OSHA: 134.9% dose, TWA 92.2 dBA, and 116.0% (91.1 dBA) against the PEL. NIOSH: 554.0%, TWA 92.4 dBA. The calculator above is filled in with this shift. The numbers are illustrative.

Same noise, different answers

The exchange rate. OSHA halves the time allowed for every 5 dB; NIOSH for every 3 dB, the rate it says is better supported by the evidence on hearing loss. At 95 dBA OSHA allows 4 hours and NIOSH 47 minutes 37 seconds.

The limit. 100% means 90 dBA for 8 hours under the OSHA PEL and 85 dBA for 8 hours under NIOSH. That is why the NIOSH dose is usually several times the OSHA dose: 554% against 134.9% in the example.

The TWAs end up close. The TWA is the steady level that would give the same dose in 8 hours, so a steady 8 hours at 88 dBA is a TWA of 88 dBA under both. When the level varies, the 3 dB rule gives the loud periods more weight, so the NIOSH TWA comes out a little higher (92.4 against 92.2 dBA in the example). Compare a TWA with the limit of the same system.

Which one applies. In U.S. general industry, OSHA's 1910.95 is the rule an inspector enforces. The NIOSH limit is a recommendation; OSHA's Technical Manual notes that NIOSH, EPA, ACGIH and most other countries use a 3 dB exchange rate. Many plants run their hearing program to the stricter number. Check your own country's rule outside the U.S.

What reaching a limit means. At the OSHA action level: noise monitoring, telling employees the results, baseline and annual audiograms, hearing protectors offered free, yearly training and records (1910.95(c) to (o)). Over the PEL: feasible engineering or administrative controls first, and hearing protectors when they are not enough (1910.95(b)(1)). Table G-16 stops at 115 dBA for a quarter hour or less, and OSHA reads it as a ceiling: no continuous noise above 115 dBA, whatever the dose. Over the NIOSH limit, NIOSH recommends a hearing loss prevention program.

Removing loud time is not the only way down. Moving people away from the source, enclosing it or fixing worn machines lowers the level itself. Record each fix like any other safety action, for example on a job safety analysis, and measure again afterwards.

Time allowed per day

Worked out from the two formulas above, the same way the calculator does, and rounded to the minute. They agree with OSHA's Table G-16a and NIOSH's Table 1-1.

Time allowed per day at each A-weighted level under OSHA and NIOSH
LevelOSHANIOSH
80 dBA32 h25 h 24 min
82 dBA24 h 15 min16 h
85 dBA16 h8 h
88 dBA10 h 33 min4 h
90 dBA8 h2 h 31 min
92 dBA6 h 4 min1 h 35 min
94 dBA4 h 36 min1 h
95 dBA4 h48 min
97 dBA3 h 2 min30 min
100 dBA2 h15 min
105 dBA1 h5 min
110 dBA30 min1 min
115 dBA15 min28 s

OSHA counts levels from 80 dBA for the action level and from 90 dBA for the PEL; NIOSH counts levels from 80 dBA. Sources: 29 CFR 1910.95 Appendix A and NIOSH Publication 98-126, sections 1.1 and 1.3.3. Checked October 9, 2026.

Embed this calculator

Teaching this, or writing about it? Paste this code into your site, course page or intranet and the calculator works right there. It is free, with no sign-up.

<iframe src="https://www.theleansuite.com/tools/noise-dose-calculator/embed" title="Noise dose and TWA calculator by LeanSuite" width="100%" height="2600" style="border:0;max-width:1000px" loading="lazy" allow="clipboard-write"></iframe>
<p style="font:13px/1.4 sans-serif"><a href="https://www.theleansuite.com/tools/noise-dose-calculator">Noise dose and TWA calculator</a> by LeanSuite</p>

How LeanSuite helps

LeanSuite does not measure noise. Its safety project management runs each corrective action, such as a noise control on a loud machine, as a project with an owner, a workflow and due dates, next to near misses, JSAs and incident rates.

See Continuous Improvement for Safety

FAQ

Noise dose and TWA calculator: common questions

More free lean tools

All tools

Pass it on

We want LeanSuite to be the best place on the internet for lean help. If this was useful, send it to someone on your team or in your network who needs it.