Skip to content
LeanSuite

Updating standard work after an improvement: re-study, revise, train and audit

Short answer

After an improvement, standard work is updated in six steps: study the current method, trial the change, re-study the new method, revise and reissue the documents, train every operator on every shift, then audit against the new time. Until all six are done, the old standard is still the standard.

An improvement is not finished when the new method works once. Run it as a dated trial beside the posted standard. Time it again over several cycles, with the same element breakdown as the original study. If the new time holds and nothing got worse for quality or safety, reissue the capacity table, the combination table and the chart together under a new revision, take every copy of the old one down and train every shift. Then audit: time a few cycles against the new standard time and ask about any cycle that stands out. Re-study also when the method, the tooling, the volume or the product changes, even if nobody set out to improve anything.

Last reviewed:

The loop: study, change, re-study, revise, train, audit

The loop that keeps standard work true

Example numbers
1

Study

Time the posted method: 71 s

2

Change

Trial a new method, dated and signed

3

Re-study

Time the new method: 63 s

71 s to 63 s

Revision A to B

6

Audit

Time ten cycles against 63 s

5

Train

Every operator, every shift, signed off

4

Revise

Reissue all three documents as revision B

Six steps in a loop: study the posted method at 71 seconds, change it on a dated trial, re-study the new method at 63 seconds, revise the documents, train every operator, then audit against 63 seconds, and back to study.

An improvement is not finished when the new method works. It is finished when the old sheet is off the wall, the new one is up, everyone is trained on it and an audit shows the cell runs at 63 s. Then the loop starts again from the new standard.

Standard work is a baseline. The Lean Enterprise Institute's Lean Lexicon describes it, once established and displayed, as the object of continuous improvement through kaizen. So a standard is supposed to be replaced. The risk is in how. Most plants are good at the change and poor at the paperwork that follows, and six months later the chart on the wall describes a job nobody does.

  1. 1

    Study the posted method

    Time the job as the current chart describes it, element by element. This is the before. If the floor already differs from the chart, record what is really done and say so.

  2. 2

    Change it as a trial

    Try the new method on one shift for a set period. Post a sheet marked TRIAL beside the standard, with an owner and an end date.

  3. 3

    Re-study the new method

    Time it again with the same elements and the same rules as the first study, once operators have settled into it. Check quality and safety results for the trial period.

  4. 4

    Revise the documents

    Reissue the capacity table, the combination table and the chart together under a new revision. Update any work instruction the change touched. Remove the old copies.

  5. 5

    Train every operator

    Teach the new sequence to everyone who runs the job, on every shift, and record it. Include the people who cover breaks and absences.

  6. 6

    Audit against the new time

    In the first weeks, time a few cycles against the new standard time and check the sequence and the stock. Then carry on at your normal audit rhythm.

This is PDCA applied to one job. The trial is the do, the re-study is the check, and the reissue is the act. What makes it stick is the fifth and sixth steps, which are the ones that get dropped when the kaizen event ends on a Friday.

Worked example: a 71 second cycle becomes 63

Illustrative numbers. A valve body cell runs to revision A: one operator, four machines, 57 seconds of manual work and 14 of walking, a 71 second cycle against an 80 second takt time. The team sees two things in the study. Deburring and gauging are done at two places on the bench with a reach between them, and the leak tester and the casting rack each sit a step further out than they need to.

Illustrative: revision A and revision B of the work sequence, times in seconds
ElementRev A manualRev A walkRev B manualRev B walkWhat changed
1. Unload and load the lathe, start it9292Nothing
2. Unload and load the mill, start it112112Nothing
3. Unload and load the drill, start it8382Leak tester moved one step closer
4. Unload and load the leak tester, start it7272Nothing
5. Deburr and gauge the bore14291Deburr tool and gauge on one fixture
6. Pack the part, pick up a casting8382Casting rack moved one step closer
Total57145211Cycle 71 s to 63 s

Revision A: 57 + 14 = 71 seconds. Revision B: 52 + 11 = 63 seconds. Takt time is 80 seconds in both.

Revision A and revision B of the combination table

Example numbers
  • Manual work
  • Machine runs alone
  • Walking
  • Waiting
  • Takt time

Revision A

71 s cycle

The posted standard before the kaizen.

  1. 1. Unload and load the lathe, start itManual 9 s, machine 42 s, walk 2 s

  2. 2. Unload and load the mill, start itManual 11 s, machine 55 s, walk 2 s

  3. 3. Unload and load the drill, start itManual 8 s, machine 28 s, walk 3 s

  4. 4. Unload and load the leak tester, start itManual 7 s, machine 20 s, walk 2 s

  5. 5. Deburr and gauge the boreManual 14 s, walk 2 s

  6. 6. Pack the part, pick up a castingManual 8 s, walk 3 s

  7. Operator cycleManual 57 s + walk 14 s = 71 s, wait 9 s

Revision B

63 s cycle

Re-studied over ten cycles after two weeks of running the new method.

  1. 1. Unload and load the lathe, start itManual 9 s, machine 42 s, walk 2 s

  2. 2. Unload and load the mill, start itManual 11 s, machine 55 s, walk 2 s

  3. 3. Unload and load the drill, start itManual 8 s, machine 28 s, walk 2 s

    Leak tester moved one step closer: walk 3 s to 2 s

  4. 4. Unload and load the leak tester, start itManual 7 s, machine 20 s, walk 2 s

  5. 5. Deburr and gauge the boreManual 9 s, walk 1 s

    Deburr tool and gauge on one fixture: 14 s to 9 s

  6. 6. Pack the part, pick up a castingManual 8 s, walk 2 s

  7. Operator cycleManual 52 s + walk 11 s = 63 s, wait 17 s

Two combination tables for the valve body cell with takt time at 80 seconds. Revision A: manual 57 seconds, walking 14 seconds, cycle 71 seconds. Revision B: manual 52 seconds, walking 11 seconds, cycle 63 seconds.

The re-study is what turns "it feels quicker" into a number. Deburr and gauge fell from 14 s to 9 s and walking from 14 s to 11 s, so the cycle is 63 s. Rows 1 to 4 did not change, and the table says so.

The trial ran for two weeks on day shift. The re-study, over ten cycles in the second week, gave 63 seconds. Rework at the gauge did not rise. So revision B was issued: a new combination table, a new chart with the moved stations and the new walking path, and a changed work instruction for element 5 showing the single fixture. The capacity table was checked and left alone, since no machine time changed.

One more check came from the combination table. The mill needs 11 + 55 = 66 seconds from the operator's arrival to the end of its cycle. With a 63 second cycle, an operator who went straight round would be back before the mill had finished. Here that cannot happen, because the operator works to the 80 second takt time and waits 17 seconds each cycle. But it means the new sheet must show the waiting, and it is a warning for the day takt time drops.

Change control for a posted standard

There should be one live standard for a job at any moment, and everyone should be able to tell which it is. That is all change control means here. It does not need a committee. It needs a few habits.

Change control: one live standard at a time

Example numbers
  1. 1Standard

    Revision A posted

    71 s cycle. This is what operators are trained on and audited to.

  2. 2Temporary

    Trial sheet beside it

    Marked TRIAL, with an owner, a start date and an end date. One shift, two weeks.

  3. 3Approval

    Re-study and approve

    63 s over ten cycles, no quality or safety problem. Supervisor, engineer and quality sign.

  4. 4Standard

    Revision B posted

    All three documents reissued the same day. Every copy of revision A removed.

A time line of four stages. Revision A is the live standard. A trial sheet marked with an owner and dates runs beside it for two weeks on one shift. The new method is re-studied and approved. Revision B replaces revision A everywhere on the same day.

The trial is the step most plants skip. Without it, operators either change the method with no paper, or follow paper that everyone knows is wrong. A dated trial sheet makes the change legal while it is being proved.
  • A revision letter and a date on every sheet, and the name of who approved it.
  • One line saying what changed and why, so the next person can see the history.
  • A trial sheet for changes being tested, marked TRIAL, with an owner, a start date and an end date. When the end date passes, it becomes the standard or it comes down.
  • All linked documents changed together: the combination table, the chart, the capacity table if machine times or tool changes moved, and any work instruction for a changed element.
  • Every old copy removed the day the new one goes up, including the one in the supervisor's binder and the photo on the tablet.
  • A training record for each operator against the new revision.
  • Approval by the people who carry the risk: usually the supervisor, the engineer and quality, plus safety when the path or the guarding changes.

Two kinds of change need more than this. If the improvement alters a product characteristic, a control plan item or anything a customer has approved, it goes through your quality system's change process before the trial, not after. If it changes how people interact with a machine, the risk assessment is reviewed first. A faster cycle is never a reason to skip either.

Auditing standard work against the standard time

An audit of standard work asks three things, in this order: is the sequence on the chart the one being followed, is the standard in-process stock right, and does the cycle take the time the standard says? The first two can be seen. The third has to be timed.

Illustrative: ten cycles timed at an audit of revision B, standard time 63 seconds
Cycle12345678910
Seconds62646361666371626463
Against standardminus 1plus 10minus 2plus 30plus 8minus 1plus 10

Sum 639 seconds, mean 63.9 seconds. On cycle 7 the operator re-gauged a part that read on the limit.

A standard work audit: ten cycles against the standard time

Example numbers
  • Standard time, 63 s
  • Takt time, 80 s
  • Cycle to ask about
  1. 62seconds, cycle 1
  2. 64seconds, cycle 2
  3. 63seconds, cycle 3
  4. 61seconds, cycle 4
  5. 66seconds, cycle 5
  6. 63seconds, cycle 6
  7. 71seconds, cycle 7
  8. 62seconds, cycle 8
  9. 64seconds, cycle 9
  10. 63seconds, cycle 10

Ten timed cycles of 62, 64, 63, 61, 66, 63, 71, 62, 64, 63 seconds, drawn as columns against a standard time of 63 seconds and a takt time of 80 seconds. Nine cycles are between 61 and 66 seconds. Cycle 7 took 71 seconds.

Nine of ten cycles sit within 3 s of the 63 s standard. Cycle 7 took 71 s: the operator re-gauged a part. The mean of 63.9 s would hide that. Plot every cycle and ask about the one that stands out.
  • Time whole cycles from a fixed point, such as pressing start on the first machine. Ten is a reasonable handful for a one-minute job. It is a check, not a new study.
  • Write down every cycle, not the average. The mean here is 63.9 seconds, which looks like a pass and hides the one cycle worth talking about.
  • Ask about the odd cycle on the spot. A re-gauge, a stuck part or a missing tool each point to a different fix.
  • If most cycles run slow, the method on the floor has drifted from the chart, or the chart was optimistic. Find out which before you say anything about pace.
  • If most cycles run fast, look for a skipped check before you celebrate. If nothing was skipped, the operator has found a better way and the loop starts again.
  • Decide your own tolerance and your own frequency, and write them on the audit sheet. They depend on the job, and no table can set them for you.

How the audit is done matters as much as what it finds. Say what you are timing and why before you start. Stand where the operator can see you. Show them the numbers afterwards. The audit is of the standard, and a gap is a question about the job: the layout, the tools, the parts, the training. Use it to judge a person and you will get one careful cycle while you watch and no honest information after that. The standard work audit checklist has the questions on one page.

When to re-study, even without an improvement

A standard goes out of date in four ways. Only one of them is a kaizen. The other three arrive from engineering, purchasing or the customer, often with no word to the person who owns the chart.

Checklist: what triggers a re-study, and which documents to reissue
TriggerExamplesRe-studyReissue
MethodA kaizen, a new sequence, a moved bench, a combined or split element, a second operator added.The changed elements and every walk that touches them.Combination table and chart. Work instruction for a changed element.
Tooling or equipmentA new fixture, a faster program, a different tool life, a machine replaced, a guard or sensor added.Manual and machine time at that machine, and the tool change time and interval.Capacity table first, then the combination table. The chart if the layout moved.
VolumeCustomer demand up or down, a shift added or removed, a change in working time.Nothing needs timing at first. Recalculate takt time and redraw the takt line.All three if the sequence no longer fits or the staffing changes. The chart always, because takt time is printed on it.
ProductA new part number in the cell, an engineering change, a new material, an added check.Every element the part touches differently. The whole cycle for a new part.A set of documents per part or part family where the times differ.

Add a fifth line of your own for time: if nothing has triggered a review for a year, walk the job with the chart anyway.

Volume is the trigger people miss, because nothing in the cell looks different. Suppose demand for the valve body rises from 345 to 400 a shift. Takt time falls from 80 to 27,600 / 400 = 69 seconds. Revision A, at 71 seconds, could not have met it. Revision B at 63 seconds fits with 6 seconds of waiting, and the mill's 66 seconds is now only 3 seconds inside the operator's return. The capacity table says the mill can make 405 a shift against 400 needed. The cell works on paper and has no slack left, which is exactly what the documents are for telling you.

A volume change moves the takt line

Example numbers
  • Old takt time, 80 s (345 a shift)
  • New takt time, 69 s (400 a shift)
  1. Revision A: 71 s2 s over the new takt time. Cannot be run.

  2. Revision B: 63 s6 s inside the new takt time.

  3. Mill, load to finish: 66 sDone 3 s before the operator is back. Capacity 405 a shift against 400.

Demand rises from 345 to 400 pieces a shift, so takt time falls from 80 to 69 seconds. Revision A at 71 seconds no longer fits. Revision B at 63 seconds fits with 6 seconds to spare.

Nothing changed in the cell, and the standard still went out of date. At 400 pieces a shift, takt time is 27,600 / 400 = 69 s. The old 71 s cycle is 2 s over. The improved 63 s cycle fits, with 6 s of waiting to put on the new sheet.

When demand moves by more than one operator's worth of work, the question becomes staffing. How many operators a line needs covers that sum, and line balancing covers sharing the elements out again.

Checklist: is the update finished?

Closing checklist for an update to standard work
CheckDone when
Before study on fileElement times for the old method are recorded, with the date and who timed them.
Trial was datedThe trial sheet had an owner and an end date, and has now come down.
Re-study doneThe new method was timed over several cycles with the same elements as the before study.
Quality and safety checkedDefects, rework and incidents for the trial period were looked at, and any risk assessment was reviewed.
Three checks passSlowest machine under takt time, operator cycle at or under takt time, every machine done before the operator returns.
Documents reissued togetherCapacity table, combination table, chart and affected work instructions carry the same new revision and date.
Old copies goneNo copy of the old revision is at the cell, in a binder or on a screen.
Everyone trainedEach operator on each shift, and each relief operator, is recorded against the new revision.
Standard WIP recountedThe number on the chart matches the marked places in the cell.
First audit doneCycles were timed against the new standard time and the result is on the audit sheet.
Saving recorded honestlyThe time saved is logged as what it is: capacity freed, or waiting, until output or staffing changes.

The last line is there for a reason. Eight seconds off a cycle is real, but it is not money until something else changes: more pieces sold, overtime removed, or a person moved to other work. Hard savings vs soft savings explains how to agree that with finance.

Common mistakes

  • Changing the floor and not the paper. The chart becomes decoration and audits become arguments.
  • Changing the paper and not the floor. A new sheet is posted and one shift never hears about it.
  • Skipping the re-study. The claimed saving is an estimate from the kaizen event, and nobody knows the real time.
  • Re-studying on day one. Times are slow while operators are learning. Let the method settle before you time it.
  • Reissuing one document. The chart says 63 seconds and the combination table in the file still says 71.
  • Making the trial permanent by neglect. A TRIAL sheet with last quarter's end date is an uncontrolled standard.
  • Auditing with the average. One mean hides the cycles that carry the information.
  • Turning the saved seconds into a higher target the next morning. People stop offering improvements, and the loop stops with them.

That last one is the people side of this whole page. Operators find most of the improvements, and they will keep finding them if a better method leads to an easier job and a say in what happens with the time. Agree before the kaizen what a saving will be used for.

Where software helps

The re-study is where the loop usually breaks, because a second stopwatch study feels like doing the work twice. LeanSuite's Time and Motion Study works from video: film the job before and after, let the AI draft the element times for you to check and certify, and keep both studies as records that link back to the footage. Once the method is settled, digital work instructions put the current version in front of the operator at the station, so the old one is not left hanging on a wall. The standard work sheet and the combination table are free LeanSuite templates.

Standardized work software

Keep standard work current in LeanSuite

LeanSuite covers most of the cycle in one platform: working out the standard with Vision AI, keeping it current with SOPs and work instructions, and training and auditing it.

Free templates and tools

FAQ

Questions about updating standard work after an improvement

  1. Run the new method as a dated trial, then time it again over several cycles with the same elements as the original study. If the time holds and quality and safety are no worse, reissue the capacity table, combination table and chart under a new revision, remove the old copies, train every shift and audit against the new time.

  2. Whenever one of four things changes: the method, the tooling or equipment, the volume, or the product. A kaizen is a method change. A demand change moves takt time and can put a sound sequence out of date overnight. If nothing has triggered a review for a year, walk the job with the chart anyway.

  3. Stand at the job with the chart and check three things: the sequence being followed matches the chart, the standard in-process stock is right, and the cycle takes the standard time. Time about ten whole cycles, write each one down and ask about any that stands out. Treat a gap as a question about the job, not the person.

  4. Find out whether the floor or the paper is wrong. If cycles run slow, the method has drifted, something is making the job harder or the standard was optimistic. If they run fast, check that no step was skipped. If none was, the operator has found a better method, so trial it, re-study it and reissue the standard.

  5. Usually the supervisor or team leader who owns the job, the engineer who timed it and quality, with safety added when the walking path, the guarding or the handling changes. Changes that affect a product characteristic or a customer-approved process go through the plant's formal change process before any trial.

  6. Because the saving claimed at the end of a kaizen is an estimate. A re-study gives the real element times for the new method, shows which elements changed and which did not, and provides the new standard time that training and audits will use. Wait until operators have settled into the method before timing it.

Or browse the topics, the full library and the lean glossary.

Rather see it on your own problem?

Bring the problem you are stuck on, and we will show you on a call how LeanSuite handles it.

Pass it on

We want LeanSuite to be the best place on the internet for lean help. If this was useful, send it to someone on your team or in your network who needs it.